DWL-2 Adhesive-Lined Dual-Wall Heat Shrink Tubing (3:1 / 4:1)

DWL-2 has a polyolefin outer wall and a hot-melt adhesive inner layer, with 3:1 and 4:1 shrink ratios and a -55 to 125 °C service range. The adhesive melts during shrinkage to seal connectors, splices and cable joints against water and moisture.

3:1 / 4:1
Shrink ratio
Polyolefin outer wall with hot-melt adhesive inner layer
Material
600V
Withstand voltage
DWL-2 Adhesive-Lined Dual-Wall Heat Shrink Tubing (3:1 / 4:1)

Key specifications

Part numberDWL-2
Product typeAdhesive-linedheat shrink tubing
Size rangeID 1.6~100mm
Shrink ratio3:1 / 4:1
MaterialPolyolefin outer wall with hot-melt adhesive inner layer
Withstand voltage600V

Standard sizes

Spec Ø (mm)Expanded ID (mm)Expanded wall (mm)Fully recovered max ID (mm)Fully recovered wall (mm)
Φ1.62.20±0.300.30±0.08≤0.700.60±0.12
Φ2.43.00±0.400.35±0.08≤0.800.70±0.12
Φ3.24.00±0.400.40±0.09≤1.051.00±0.15
Φ4.85.50±0.400.45±0.11≤1.601.10±0.15
Φ6.47.50±0.400.45±0.11≤2.101.25±0.15
Φ7.98.50±0.400.50±0.12≤2.701.30±0.15
Φ9.510.5±0.600.55±0.12≤3.101.35±0.15
Φ12.713.5±0.600.60±0.15≤4.201.60±0.20
Φ15.416.6±0.800.65±0.17≤5.101.75±0.20
Φ19.120.5±1.000.65±0.17≤6.301.85±0.20
Φ25.426.5±1.000.75±0.20≤8.402.05±0.20
Φ3032.0±1.600.75±0.20≤10.02.10±0.20
Φ3941.0±1.600.85±0.25≤13.02.55±0.20
Φ50.853.0±2.000.85±0.25≤17.22.75±0.25

Typical test data

PropertyRequirementTest methodTypical value
Longitudinal shrinkage (200±5°C×3min)±10%ASTM D 2671±7%
Eccentricity≤35%ASTM D 267115%
Tensile strength≥9.0 MPaASTM D 63810 MPa
Elongation at break≥250%ASTM D 638500%
Elongation after ageing (158°C×168h)≥100%ASTM D 638300%
Cold bend (-55°C×4h)No cracksASTM D 2671Pass
Volume resistivity≥10¹² Ω·cmASTM D 87610¹⁴ Ω·cm

Where it is used

  • Automotive harness joints
  • Electronic connectors and terminals
  • Telecom equipment and base stations
  • Outdoor lighting and sensors
  • Cable repair and splicing

Request a datasheet, sample or quote

Send the size range, operating temperature and delivery requirement. We will reply with the recommended construction, wall thickness, shrink ratio and a sample plan.